成人免费看久久久a片,欧美另类videosbestsex牲,亚洲精品永久在线观看,国产suv精品一区二区62

sales@gninstruments.com

Type:CX-ICM-1101 industrial conductivity meter

Illustrate:Widely used for continuous monitoring of the conductivities of solutions used in the following fields: thermal power plant, chemical fertilizer, chemical industry, metallurgy, environmental protection, pharmacy manufacturing, biochemistry, foodstuff and running water.

CX-ICM-1101 industrial conductivity meter

Brief Introduction
1.It is our company’s latest top-class instrument equipped with a microprocessor
2.It is characterized by its intelligent operation, multi-function and high measuring performance and its strong environmental adaptability
 
Main Features
1.Display:conductivity, output current, temperature, time and status.
2.Bitmap type liquid crystal display modulewith high resolution is adopted.
3.Thereis no symbol or code that is defined by the manufacturer.
 
Main Parameters

Measuring range 0.01~20μS/cm(Electrode:K=0.01),00.1~200μS/cm
(Electrode: K=0.1)
1.0~2000μS/cm(Electrode:K=1.0),10~20000μS/cm
(Electrode:K=10.0)                       
30~600.0mS/cm  (Electrode: K=30.0)
Intrinsic error of the electronic unit 2. : conductivity: ±0.5%FS, temperature: ±0.30C
Automatic temperature compensation 0~99.9C, with 25C as the reference temperature
Water sample tested 0~99.9C, 0.6MPa
Intrinsic error of the instrument Conductivity: ±1.0%FS, temperature: ±0.5C
Automatic temperature compensation error ±0.5%FS
Repeatability error ±0.2%FS±1 Unit
Stability ±0.2%FS±1 unit/24h
Isolated current output 0~10mA ( load<1.5kΩ),4~20mA (load<750Ω)
Output current error ≤±l%FS
Error caused by ambient temperature ≤±0.5%FS
Error caused by the supply voltage  ≤±0.3%FS
Alarm relay  AC 220V, 3A
Communication interface RS485 or 232 (optional)
Power supply AC 220V±22V, 50Hz±1Hz
Protection grade IP65
Clock accuracy ±1 minute/month
Data storage capacity l month (1 point/5 minutes)
The time for Saving data 10 years
Overall dimension 146 (length) x 146 (width) x 108 (depth) mm;
Dimension of the hole 138 x 138mm
Working conditions ambient temperature0~60C; relative humidity <85%
Note: The conductivity electrodes with the following five constants are usable: K=0.01, 0.1, 1.0, 10.0, and 30.0.

Last:CX-ICM-1101A industrial conduct.. Next:CX-ICM-1104 industrial conducti..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關閉
主站蜘蛛池模板: 象州县| 张掖市| 青川县| 永泰县| 贵港市| 安龙县| 类乌齐县| 海淀区| 洪雅县| 拜泉县| 铁岭市| 遂昌县| 合江县| 沁水县| 重庆市| 钟祥市| 莱阳市| 绍兴县| 甘洛县| 祁阳县| 英吉沙县| 上虞市| 淳安县| 建昌县| 长子县| 金乡县| 中牟县| 吉隆县| 桑日县| 乌审旗| 互助| 平遥县| 恩平市| 沙雅县| 姜堰市| 星座| 古丈县| 阿荣旗| 平湖市| 邹城市| 建湖县|