Type:CX-ICPW industrial composite pure water ph electrode

Illustrate:The composite electrode make it ideal for measuring PH value of high-purity water.

Model No.: CX-ICPW-1703
Measuring range: 0-14pH
Temperature range:0-85C
Compressive strength:0.6MPa
Material: PPS/PC
Slope: ≥96%
Zero point potential: E0=7PH±0.3
Internal impedance:
MΩ(25C) ≤250 MΩ
Installation size: Upper and Lower 3/4NPT Pipe Thread
Connection: Low-noise cable goes out directly.
Application: Measurement of all kinds of pure water and high-purity water.

Model No.: CX-ICPW-1704
Measuring range: 0-14pH
Temperature range:0-85C
Compressive strength:0.6MPa
Slope: ≥96%
Zero point potential: E0=7PH±0.3
Internal impedance: MΩ(25C) ≤250 MΩ
Profile:3-in-1Electrode (Integrating the temperature compensation and the solution grounding)
Installation size: Upper and Lower 3/4NPT Pipe Thread
Connection: Low-noise cable goes out directly.
Application: Measurement of all kinds of pure water and high-purity water.

Brief Introduction
The polymer filling makes the reference junction potential very stable.
The diffusion potential is very stable; large-area diaphragm surrounds the glass diaphragm bubbles, so that the distance from the reference diaphragm to the glass diaphragm is near and constant; the ions diffused from diaphragm and the glass electrode quickly form a complete measurement circuit to respond quickly, so that the diffusion potential is not easy to be affected by the outside flow rate and is thus very stable.
As the diaphragm adopts the polymer filling and there is small and stable amount of overflowing electrolyte, it shall not pollute the measured pure water.

Main Features
1. It adopts the world-class solid dielectric and a large area of PCE liquid for junction, difficult to block and
it adopts the world-class solid dielectric and a large area of PCE liquid for junction, difficult to block and
2.Long-distance reference diffusion channel greatly extends the service life of electrodes in the harsh
environment.
3.It adopts PPS/PC casing and the upper and lower 3/4NPT pipe thread, so it is easy for installation and there is
no need of the jacket, thus saving the installation cost.
4. The electrode adopts the high-quality low-noise cable, which makes the signal output length more than 40
meters free of interference.
5.There is no need for additional dielectric and there is a little amount of maintenance.
6.High measurement accuracy, fast echoing and good repeatability.
7.Reference electrode with silver ions Ag/AgCL
8.Proper operation shall make service life longer.
9.It can be installed in the reaction tank or pipe laterally or vertically.
9.The electrode can be replaced by a similar electrode made by any other country.

Last:Without the Next:CXGP90-120 High-temperature ph ..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
主站蜘蛛池模板: 江孜县| 苏尼特左旗| 遂昌县| 隆子县| 正镶白旗| 盘锦市| 云南省| 楚雄市| 安徽省| 凭祥市| 宜春市| 家居| 余干县| 清镇市| 新河县| 邓州市| 大埔县| 伊金霍洛旗| 胶州市| 抚宁县| 鄂托克前旗| 海盐县| 吉安县| 民勤县| 山西省| 肃宁县| 平凉市| 自贡市| 邵武市| 广饶县| 临潭县| 章丘市| 高台县| 磴口县| 贵州省| 东安县| 安远县| 德清县| 昭苏县| 昭平县| 玉龙|